<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>05122nam a2200409 a 4500</leader>
  <controlfield tag="001">dia_6090</controlfield>
  <controlfield tag="003">CHAP</controlfield>
  <controlfield tag="005">20241111132331.0</controlfield>
  <controlfield tag="007">ta</controlfield>
  <controlfield tag="008">220117s2009    mx ado fr     001 0 spa d</controlfield>
  <datafield tag="010" ind1=" " ind2=" ">
    <subfield code="a">177241</subfield>
  </datafield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="a">mxchpua</subfield>
    <subfield code="c">CHAP</subfield>
  </datafield>
  <datafield tag="041" ind1="0" ind2=" ">
    <subfield code="a">spa</subfield>
    <subfield code="b">atg</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">Tesis </subfield>
    <subfield code="b">L67 </subfield>
    <subfield code="c">2009</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">L&#xF3;pez Aguilar, Rosa</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Determinaci&#xF3;n de incertidumbre en pruebas de tensi&#xF3;n y comprensi&#xF3;n aplicadas a envases de alimentos /</subfield>
    <subfield code="c">Rosa L&#xF3;pez Aguilar</subfield>
  </datafield>
  <datafield tag="264" ind1=" " ind2=" ">
    <subfield code="a">Chapingo, M&#xE9;xico :</subfield>
    <subfield code="b">El autor,</subfield>
    <subfield code="c">2009</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">xi, 135 hojas :</subfield>
    <subfield code="b">ilustraciones, tablas, gr&#xE1;ficas, fotograf&#xED;as +</subfield>
    <subfield code="e">1 CD-ROM</subfield>
  </datafield>
  <datafield tag="336" ind1=" " ind2=" ">
    <subfield code="2">rdacontent</subfield>
    <subfield code="a">texto</subfield>
    <subfield code="b">txt</subfield>
  </datafield>
  <datafield tag="337" ind1=" " ind2=" ">
    <subfield code="2">rdamedia</subfield>
    <subfield code="a">no mediado</subfield>
    <subfield code="b">n</subfield>
  </datafield>
  <datafield tag="338" ind1=" " ind2=" ">
    <subfield code="2">rdacarrier</subfield>
    <subfield code="a">volumen</subfield>
    <subfield code="b">nc</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Tesis</subfield>
    <subfield code="b">(Ingeniero Agroindustrial) --</subfield>
    <subfield code="c">UACh. Departamento de Ingenier&#xED;a Agroindustrial,</subfield>
    <subfield code="d">2009</subfield>
  </datafield>
  <datafield tag="504" ind1=" " ind2=" ">
    <subfield code="a">Bibliograf&#xED;a: hojas 124-128</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">El presente trabajo propone las metodolog&#xED;as para determinar la incertidumbre expandida de las m&#xE1;quinas universales Instron Modelo A372-14 y el Textur&#xF3;metro Modelo TA-XT2i, que se encuentran en el Laboratorio de Calidad en el Departamento de Ingenier&#xED;a Agroindustrial (DIA) de la Universidad Aut&#xF3;noma Chapingo (UACh). Las m&#xE1;quinas universales se usan para medir las propiedades mec&#xE1;nicas de los materiales, principalmente a trav&#xE9;s de ensayos de tensi&#xF3;n y compresi&#xF3;n. En el D.I.A se han usado tanto el Instron Modelo A372-14, como el Textur&#xF3;metro TA-XT2i principalmente para medir caracter&#xED;sticas de textura en alimentos como por ejemplo: galleta, aguacate, fresa y tortillas de ma&#xED;z. El conocimiento de la incertidumbre de la m&#xE1;quina universal Instron Modelo A372-14 y del Textur&#xF3;metro TA-XT2i, indic&#xF3; que tan confiables son los datos obtenidos al realizar pruebas de tensi&#xF3;n y compresi&#xF3;n en dichos instrumentos. En pruebas de compresi&#xF3;n con la m&#xE1;quina Instron, con la celda de 500 kgf en un rango de medici&#xF3;n de cero hasta 50 kgf, se encontr&#xF3; una incertidumbre expandida del instrumento de 19.4 %L (porcentaje de lectura). La incertidumbre expandida de la medici&#xF3;n en pruebas a compresi&#xF3;n aplicada a diferentes envases para alimentos en la m&#xE1;quina Instron con la celda de 500 kgf, en escalas de: cero a 50 kgf, de cero a 100 kgf y de cero a 200 kgf, se encontr&#xF3; dentro del intervalo de 2.39 % L a 18.0 % L. En pruebas a tensi&#xF3;n en el Textur&#xF3;metro con la celda de 5 kgf, la incertidumbre expandida del instrumento fue de 0.410 %L, mientras que con la celda de 25 kgf ese par&#xE1;metro fue de 0.544 %L. La incertidumbre expandida de la medici&#xF3;n en pruebas de tensi&#xF3;n aplicada a los diferentes materiales de envase en el Textur&#xF3;metro con la celda de 5 kgf se encontr&#xF3; dentro del rango de 4.51 %L a 6.80 %L y para la celda de 25 kgf el rango fue de 4.12 %L a 8.90 %L</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">This work proposes the methodologies for determining the expanded uncertainty of the universal machines Instron Model A372-14 and the Texture analyzer Model TA-XT2i, who are in the Laboratory of Quality in the Departamento de Ingenier&#xED;a Agroindustrial (D.I.A.) of the Universidad Aut&#xF3;noma Chapingo (UACh). The universal machines are used to measure the mechanical properties of materials, mostly through tests of tensile and compression forces. In the D.I.A. have been used both the Instron Model A372-14, as the Texture analyzer TA-XT2i mainly to measure characteristics of texture in food such as: cookie, avocado, strawberry and corn tortilla. The knowledge of the uncertainty of the universal machine Instron Model A372-14 and the Texture analyzer TA-XT2i, indicated that as reliable are the data obtained when testing tension and compression in these instruments. In compression test with the 500 kgf cell by the universal machine Instron and a range of measuring for cero to 50 kgf the expanded uncertainty of the instrument was: 19.4 %M (percent of measurement). In tests to compression applied to several packages by the machine Instron with the cell 500 kgf in scales from: zero to 50 kgf, the zero to 100 kgf and zero to 200 kgf, the expanded uncertainty of the measurement found within the range from 2.39 %M to 16.80 %M. In tensile test whit Texture analyzer with the 5 kgf cell, the expanded uncertainty of the instrument was: 0.410 %M, and for the 25 kgf cell was 0.544 %M. In tensile force test applied to food packaging materials by the Texture analyzer with the 5 kgf cell, the expanded uncertainty of the measurement found within the range from 4.51 %M to 6.80 %M and with the 25 kgf cell it found within the range between 4.12 %M and 8.90 %M.</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="3">
    <subfield code="a">Maquinaria</subfield>
    <subfield code="2">atg</subfield>
    <subfield code="x">An&#xE1;lisis de incertidumbre</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="3">
    <subfield code="a">Recipientes</subfield>
    <subfield code="2">atg</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="3">
    <subfield code="a">Containers</subfield>
    <subfield code="2">atg</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="3">
    <subfield code="a">Machinery</subfield>
    <subfield code="x">Uncertainty analysis</subfield>
    <subfield code="2">atg</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Reyes Vigil, Miguel</subfield>
    <subfield code="e">director</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Ba&#xF1;uelos Gudi&#xF1;o, Mario Marco Vinicio</subfield>
    <subfield code="e">asesor</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Hern&#xE1;ndez Montes, Arturo</subfield>
    <subfield code="e">asesor</subfield>
  </datafield>
  <datafield tag="901" ind1=" " ind2=" ">
    <subfield code="a">TESIS L67 2009</subfield>
  </datafield>
  <datafield tag="902" ind1=" " ind2=" ">
    <subfield code="a">M</subfield>
  </datafield>
  <datafield tag="905" ind1=" " ind2=" ">
    <subfield code="a">5232272009                          mx dnml8223123322spa16</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">TESIS</subfield>
    <subfield code="2">Clasificaci&#xF3;n Universidad Aut&#xF3;noma Chapingo</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">177241</subfield>
    <subfield code="d">177241</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">local</subfield>
    <subfield code="4">0</subfield>
    <subfield code="5">5</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">TESIS</subfield>
    <subfield code="a">IA_</subfield>
    <subfield code="b">IA_</subfield>
    <subfield code="d">2022-01-18</subfield>
    <subfield code="e">El autor</subfield>
    <subfield code="l">1</subfield>
    <subfield code="o">Tesis L67 2009</subfield>
    <subfield code="p">1101009701</subfield>
    <subfield code="r">2024-11-15 16:54:35</subfield>
    <subfield code="s">2024-11-15</subfield>
    <subfield code="t">Ej.3</subfield>
    <subfield code="w">2022-01-18</subfield>
    <subfield code="y">CD</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">local</subfield>
    <subfield code="4">0</subfield>
    <subfield code="5">1</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">TESIS</subfield>
    <subfield code="a">IA_</subfield>
    <subfield code="b">IA_</subfield>
    <subfield code="d">2022-01-18</subfield>
    <subfield code="e">El autor</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">Tesis L67 2009</subfield>
    <subfield code="p">1101009699</subfield>
    <subfield code="r">2026-02-02 00:00:00</subfield>
    <subfield code="t">Ej.1</subfield>
    <subfield code="w">2022-01-18</subfield>
    <subfield code="y">TESIS</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">local</subfield>
    <subfield code="4">0</subfield>
    <subfield code="5">5</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">TESIS</subfield>
    <subfield code="a">IA_</subfield>
    <subfield code="b">IA_</subfield>
    <subfield code="d">2022-01-18</subfield>
    <subfield code="e">El autor</subfield>
    <subfield code="l">1</subfield>
    <subfield code="o">Tesis L67 2009</subfield>
    <subfield code="p">1101009700</subfield>
    <subfield code="r">2026-02-02 00:00:00</subfield>
    <subfield code="s">2024-11-15</subfield>
    <subfield code="t">Ej.2</subfield>
    <subfield code="w">2022-01-18</subfield>
    <subfield code="y">TESIS</subfield>
  </datafield>
</record>
